Symptoms:
One or more Intel X710 (i40en) VMNIC interfaces experience persistent link flapping (Up/Down).
vCenter reports "Network uplink redundancy lost" and "Network uplink redundancy restored" in rapid succession.
The following events are seen in vobd.log
2026-03-22T01:54:49.844Z In(14) vobd[2098051]: [netCorrelator] 420311338626us: [vob.net.dvport.uplink.transition.down] Uplink: vmnic# is down. Affected dvPort: ##/# ## ## ## ## ## ## ##-## ## ## ## ## ## ## ##. # uplinks up. Failed criteria: 128
2026-03-22T01:54:49.844Z In(14) vobd[2098051]: [netCorrelator] 420311338702us: [vob.net.vmnic.linkstate.down] vmnic vmnic# linkstate downThe vmkernel.log contains netschedHClk (Network Scheduler) watchdog errors:
2026-03-22T01:54:49.843Z In(182) vmkernel: cpu56:2098354)i40en: i40en_UpdateUplinkLinkStatus:7043: ####:##:##.#: Link is down for device
2026-03-22T01:54:49.843Z In(182) vmkernel: cpu56:2098354)Uplink: 65: update uplink: vmnic#, state: 0
2026-03-22T01:54:49.844Z In(182) vmkernel: cpu56:2098354)netschedHClk: NetSchedHClkNotify:5069: vmnic#: link down notification
2026-03-22T01:54:49.844Z In(182) vmkernel: cpu56:2098354)Uplink: 14587: vmnic# link state 0 speed 0 half duplex
2026-03-22T01:54:50.501Z In(182) vmkernel: cpu28:3053988)netschedHClk: NetSchedHClkWatchdogSysWorld:7126: vmnic#: failed to get the coalescing settings: Not supported
2026-03-22T01:54:50.501Z In(182) vmkernel: cpu28:3053988)netschedHClk: NetSchedHClkWatchdogSysWorld:7146: vmnic#: failed to push the coalescing settings, increase inflight window to 172920 bytes: Not supported
2026-03-22T01:54:50.501Z In(182) vmkernel: cpu21:2097645)NetqueueBal: 5211: vmnic#: device Up notification, reset logical space neededPhysical cable unplug/re-plug and/or Switch port changing do not resolve the issue.
The issue appeared after upgrading from VxRail 8.0.361 to 8.0.370; it can affect VxRail environments post-upgrade.
VMware vSphere ESXi