SYSMOD RO83105 DOES NOT SPECIFY RO30546 ON THE PRE OR SUP
book
Article ID: 43641
calendar_today
Updated On:
Products
QuickFetch
Issue/Introduction
You are applying maintenance to QuickFetch r2.6. You get the following error:
GIM38201E ** THERE IS A MODID ERROR FOR MOD ENTRY QFSSUBS IN SYSMOD RO83105. GIM31901I SYSMOD RO83105 DOES NOT SPECIFY RO30546 ON THE PRE OR SUP OPERAND. RO30546 IS THE RMID FOR MOD QFSSUBS THAT IS CURRENTLY INSTALLED.
Environment
Release: ESBQKF99000-2.6-QuickFetch-Extended Support-Basic for CA QuickFetch RPO Component:
Resolution
The Quickfetch were originally published for a "one at a time APPLY" scenario. We have seen this same situation occur when some APARs were not APPLYd in order or they tried a multiple APPLY process. Normally, I would say that is okay. But the way Quickfetch is packaged you must APPLY them one at a time from base or wherever you are.
You will find that RO30546 is not required for the PRE on PTF RO83105 because it was SUPing RO81511.
However, definitely start at the low members of the APARs and go one at a time.