When running the powervault_config.py script to configure new Dell ME5 storage, the following error messages are reported:
Connecting to https://<ip_address>Session Established with https://<ip_address>Unable to find initiators on external storageConfiguration file '/etc/solera/powervault/2U144.json' is invalid for storage at <ip_address>Command failed to complete.
If the sensor is not able to correctly detect the storage connected, the config script will fail. This is usually caused by incorrect cabling.
Although the "clear" and "probe" scripts may run successfully, the "config" script uses the SAS cables to run its configuration. The "clear" and "probe" scripts use the management interface on the storage arrays to both clear and probe for the expected hardware. The error "Configuration file '/etc/solera/powervault/2U144.json' is invalid" occurs because the script cannot validate the file against the hardware it cannot see.