Symptoms
- vSAN disk group or specific NVMe drive appears offline or degraded.
- The ESXi host may experience a Power-On Self-Test (POST) warning or fail to boot with a Purple Screen of Death (PSOD) showing during vSAN initialization.
#PF Exception 14- Integrated Lights-Out (iLO) or other hardware management interfaces report a 'Degraded' or 'Critical' status for the NVMe drive.-
- VMkernel logs (vobd.all) show critical health warnings: NVMe critical health warning for disk ... is: The disk's spare capacity is below threshold.
- HPP (High-Performance Path) or NvmeUtil errors are observed:
Error status H:0x0 D:0x182 P:0x0 or NVMe Cmd 0x1 ... Failed.
vSAN 8.x
This issue is caused by physical hardware failure of the NVMe drive, specifically when the drive's internal spare blocks (spare capacity) fall below the vendor-defined threshold. This triggers a critical health state that prevents vSAN from reliably using the device, often leading to driver timeouts and subsequent kernel panics (PSOD) when the host attempts to mount the failed device during boot.
The faulty NVMe drive must be replaced to restore full vSAN functionality.