On failure of a storage controller, multiple devices go APD on multiple ESXi hosts
book
Article ID: 435771
calendar_today
Updated On:
Products
VMware vSphere ESXi
Issue/Introduction
One storage controller on a storage array fails, or is otherwise taken down (e.g. for upgrade).
In this scenario, half of the paths to devices are expected to become "Dead"
However, multiple devices on multiple hosts enter an All Paths Down (APD) state.
Prior to the failure there were no errors indicating failed paths ("Path redundancy degraded").
Environment
VMware vSphere ESXi (all versions)
Cause
Certain devices only have paths available through the failed controller, due to device access configuration on the storage array.
Loss of these paths cause the devices to enter an APD state.
Resolution
Review device access configuration on the array (e.g. host initiator groups) and ensure the configuration is consistent for ESXi access to all devices.
On Fibre Channel storage, ensure zoning has been correctly configured.