Selenium script timeout on Azure Global Monitoring Point
search cancel

Selenium script timeout on Azure Global Monitoring Point

book

Article ID: 435558

calendar_today

Updated On:

Products

AppNeta

Issue/Introduction

Selenium scripts fail to load and time out after approximately 90 seconds when running from an Azure Global Monitoring Point (GMP), despite working on local physical monitoring points ․​

 

"Resource was still loading when script timed out (91.2s load) [Milestone 1] open: timeout: Timed out receiving message from renderer"

Environment

AppNeta

Cause

Broadcom-hosted Global Monitoring Points (Azure GMP) are considered external resources If the target internal URL is not explicitly permitted through the corporate firewall for external traffic, the renderer will time out waiting for the resource to load

Resolution

STEPS:

  1. VERIFY EXTERNAL ACCESSIBILITY:

    Confirm if the resource is reachable from outside the corporate network
    Attempt to access the target URL from a standard external PC or non-corporate network
    If the URL is unreachable, the issue is likely network-level rather than application-specific

     

  2. INSPECT FIREWALL RESTRICTIONS:
    Coordinate with the network security team to check for blocked traffic

    • Provide the network team with the target URL and the timeframe of the failures
      Specifically check for blocks originating from Azure/Broadcom GMP IP ranges to the internal OneClick or Web Server

     

  3. UNBLOCK EXTERNAL RESOURCES: Ensure the firewall allows traffic from the Monitoring Point

    • Request the network team to whitelist or allow traffic from the external resource to the target server port (e.g., 9443)