Issue/Introduction

 

  • Multiple Virtual Machines (VMs) are disconnected or show as "Invalid/Inaccessible."

  • VMs are not pingable and the Web Console fails to launch.

  • ESXi management agents (hostd, vpxa) are unresponsive.

  • CLI commands such as esxcli, ls, or df hang indefinitely.

  • Storage rescans fail to complete.

  • host logs, the following indicators of a storage communication breakdown were identified:

    1. VMFS Connectivity Loss

    The vobd.log confirms the host lost its heartbeat with the datastore:

    YYYY-MM-DDThh:mm:ss.000Z ... [vob.vmfs.heartbeat.timedout] #########-########-####-########## Datastore_name

    2. Driver & Path Failure

    The vmkernel.log indicates the nfnic driver (Cisco UCS) lost the transport port to the LUN:

    YYYY-MM-DDThh:mm:ss.000Z ... nfnic: <1>: INFO: fnic_queuecommand: 734: returning IO as lun is inactive or tport is NULL. driverIO:0 YYYY-MM-DDThh:mm:ss.000Z ... PowerPath:Path vmhba0:C0:T##:L### Inquiry Pirp Failed

    3. SCSI Command Aborts

    The vmkwarning.log shows the kernel unsuccessfully attempting to clear stuck I/O:

    YYYY-MM-DDThh:mm:ss.000Z ... WARNING: nfnic: <2>: fnic_abort_cmd: 3889: Abort for cmd tag: 0x1 in pending state

 

Environment

VMware vSphere ESXi

CISCO UCS Storage

Cause

The root cause is an All Paths Down (APD) event triggered by the Cisco UCS nfnic driver losing its Transport Port (tport) connection to the storage fabric.

When the tport becomes NULL, the ESXi host cannot communicate with the storage array. Because the driver failed to gracefully time out these operations, the I/O commands remained in a "pending" state, creating a software deadlock. This deadlock "wedges" the ESXi management stack, causing the CLI and UI to hang while waiting for a response from the storage subsystem.

Resolution

Additional Information

Why a reboot was required:

  • I/O Flush: It clears the kernel's stuck I/O heap that was causing the CLI/UI to hang.

  • Driver Reset: It forces the nfnic driver to re-initialize and perform a fresh Fabric Login (FLOGI), re-establishing the missing tport.

  • Lock Reclamation: It allows the host to re-establish the VMFS heartbeat and reclaim the file locks for the affected VMs.