Organization Portal > Build & Deploy > Instances > Virtual Machines > Selected Virtual Machine > Open Web Console
Error appearing above the Remote Console, as seen below:errorType: "protocolerror"
[Info ] Disconnected: illegal server message type 130VCF Automation 9.0.x
The issue is related to the connection to vCenter closing from the Console before being sent, causing the error when sending input to the Console.
As seen in the provisioning-service-app logs (/var/log/services-log/prelude/provisioning-service-app/file-logs/provisioning-service-app.log):
#-#-#T#:#:#.#Z ERROR provisioning [host='provisioning-service--####' thread='reactor-http-epoll-#' user='' org='' trace='' parent='' span=''] c.v.w.p.s.c.WebSocketClientToVCenterHost.lambda$handle$#:# - [vRA host: server.example.com communicating with vCenter Host: wss://server.example.com:#/ticket/#####]: Exception [Connection has been closed BEFORE send operation] received while sending message from client. This may be due to browser window closed by the end user. Closing open websocket sessions.
Currently, there is no resolution. This issue is scheduled to be resolved in the upcoming VCF Automation 9.1 release.
Please subscribe to this article to be notified when the release becomes available and the article is updated with download instructions.