Following a virtual machine (VM) hardware compatibility upgrade or manual recreation of the .nvram file, the guest operating system experiences an unexpected time shift (e.g., 3 to 6 hours forward) upon the first power-on.
FALSE in the .vmx file, but the shift still occurs during the hardware bootstrap phase.vmware.log for the affected VM shows the following error during initialization: vcpu-0 - pvnvram: Failed to retrieve timestamp database data.vSphere 8.x
The loss of the Paravirtualized NVRAM (pvnvram) timestamp database previously stored within the.nvramfile.
.nvram file is renamed or deleted to force recreation, the hypervisor's reconciliation database — which aligns the host's physical UTC clock with the guest's local time offset — is removed.Note: Do not change, move, or delete virtual machine files without instructions from a VMware Technical Support representative. See Virtual Machine Files documentation for further details.
To remediate the time skew and prevent future occurrences during NVRAM maintenance:
W32TM /resync.vmx file of the affected VM. This forces the virtual hardware to treat the Real Time Clock (RTC) as UTC consistently, removing the reliance on the pvnvram offset database:rtc.diffFromUTC = 0pvnvram database initializes correctly.