PVC is not bound."stderr F IMMDD hh:mm:ss.nnnnnn 1 binder.go:764] "PVC is not bound" logger="PreFilter.VolumeBinding" PVC="kasten-ns/kanister-pvc-bbbb"
stderr F IMMDD hh:mm:ss.nnnnnn 1 klogx.go:87] failed to find place for kasten-ns/copy-vol-data-####: can't schedule pod kasten-ns/copy-vol-data-xxxx: predicate "VolumeBinding" didn't pass (predicateReasons=[pod has unbound immediate PersistentVolumeClaims]; unexpectedError=PreFilter failed)
1 recorder.go:104] "Scaled MachineSet <my-namespace>/<my-machineset>: 3 -> 4" logger="events" type="Normal" object={"kind":"MachineDeployment","namespace":"<my-namespace>","name":"<my-machinedeployment>","uid":"---","apiVersion":"cluster.x-k8s.io/v1beta1","resourceVersion":"#########"} reason="SuccessfulScale"
:
1 recorder.go:104] "Scaled MachineSet <my-namespace>/<my-mschineset>: 4 -> 3" logger="events" type="Normal" object={"kind":"MachineDeployment","namespace":"<my-namespace>","name":"<my-machinedeployment>","uid":"########-####-####-####-############","apiVersion":"cluster.x-k8s.io/v1beta1","resourceVersion":"#########"} reason="SuccessfulScale"
When the Kasten backup process initiated, it attempted to deploy two pods where each requiring a specific Persistent Volume Claim (ex. kasten-ns/kanister-pvc-xxxx and kasten-ns/kanister-pvc-yyyy). These pods failed to schedule because their respective PVCs were not yet bound. Consequently, the autoscaler initiated a node scale-up; however, by the time the new node was provisioned, the PVCs had successfully bound. This rendered the additional node unnecessary, resulting in its immediate deletion.
This behavior can occur when the backend storage provider exhibits high latency during volume provisioning or binding operations.
For a permanent fix, please work with the storage provider and improve the latency of the storage operations.
As a workaround, a scale-up delay must be implemented in the Cluster Autoscaler configuration to allow for high storage latency.
Please follow below steps to adjust the scale-up delay.
1. Add the new-pod-scale-up-delay argument to the Cluster Autoscaler configuration.
If using a values.yaml for deployment, the configuration should be updated as follows:
$ vi values.yaml
arguments:
ignoreDaemonsetsUtilization: true
maxNodeProvisionTime: 15m
maxNodesTotal: 0
metricsPort: 8085
scaleDownDelayAfterAdd: 10m
scaleDownDelayAfterDelete: 10s
scaleDownDelayAfterFailure: 3m
scaleDownUnneededTime: 10m
extraArguments: ### +
- "new-pod-scale-up-delay=600s" ### +<<<--- Add param to the config.
clusterConfig:
clusterName: "tkc"
clusterNamespace: "cluster"
paused: false
2. Update the Package using the modified configuration.
$ tanzu package installed update cluster-autoscaler-pkgi -n tkg-system --package cluster-autoscaler.tanzu.vmware.com --values-file values.yaml
The 600s value (10 minutes) is a recommended starting point and should be adjusted based on the observed maximum latency of the storage provider.
For more information on Autoscaler, please check the formal documentation from Broadcom.
Autoscaling TKG Service Clusters
Related upstream Autoscaler issues -
Issue 5801: Reports unexpected scale-ups due to PVC timing.
Issue 3131: Explains the mechanism of this race condition.
Resolution - How can I modify Cluster Autoscaler reaction time?