Er(163) VVold[2098680]: [Originator@6876 sub=Default IpcCtx=2098677-40 OpId=HB-host-2032@#######-#######-########-#-####] VasaOp::DoRetry [#6104321]: No available best VP for array (com.purestorage:#######-####-####-####-#######65fe), retrying all VPs with force connect!
In(14) vobd[2097572]: [VvolCorrelator] 21663451047881us: [vob.vvol.container.offline] VVol container (vvol:###########-############) has gone offline: isPEAccessible (False), isVPAccessible (False).
VMware ESXi Version: 8.0.x
Connectivity disruption between the ESXi host and the Pure Storage VASA Provider (VP).
Engage storage array vendor to investigate the management network path between the ESXi hosts and the Pure Storage VASA provider to resolve the connectivity disruption.
The VASA provider was down due to a connectivity issue between the ESXi hosts and the storage array. As a result of this disruption, the protocol endpoint became inaccessible, which led to an outage during the affected period.
The connectivity between the ESXi hosts and the storage array needs to be thoroughly reviewed to help prevent recurrence of this issue.