@BlueScreen: #PF Exception 14 in world <ID>:vmnic#-pollWPhysMemFireTracesSlow@vmkernel#nover+0x5cPhysMem_FireTraces@vmkernel#nover+0x36Vmxnet3VMKDevDeliverPktToQueue@vmkernel#nover+0x894Vmxnet3VMKDevRxWithLock@vmkernel#nover+0xdc1Vmxnet3VMKDevRxFunc@vmkernel#nover+0x476PortOutput@vmkernel#nover+0x31dvmk_PortOutput@vmkernel#nover+0x11c[email protected]#1.0.0+0x9c[email protected]#1.0.0+0x74fPort_InputResume@vmkernel#nover+0x1bfNet_AcceptRxList@vmkernel#nover+0x25bNetPollWorldCallback@vmkernel#nover+0xb8CpuSched_StartWorld@vmkernel#nover+0xbfDebug_IsInitialized@vmkernel#nover+0xcA conflict within the Virtual Input/Output Memory Management Unit (vIOMMU) device causes this issue. The vIOMMU device interferes with the vmnic polling process during specific VM memory-trace operations, resulting in a page fault.
This is the most effective way to prevent the PSOD while maintaining operational flexibility.
If vIOMMU is strictly required for the guest OS workload, prevent vMotion and Snapshots tasks from triggering:
snapshot.maxSnapshots0To identify Impacted Virtual Machines with vIOMMU (VVTD) enabled, use the following PowerCLI command:Get-VM | Where-Object {$_.ExtensionData.Config.Flags.VvtdEnabled -eq $true} | Select-Object Name, @{N="vIOMMU_Enabled"; E={$_.ExtensionData.Config.Flags.VvtdEnabled}} | Format-Table -AutoSize
For further assistance, see Contact Support