Error: Health Check for failed Software compatibility cannot be determined during VCF upgrade
search cancel

Error: Health Check for failed Software compatibility cannot be determined during VCF upgrade

book

Article ID: 434051

calendar_today

Updated On:

Products

VMware vSAN VMware vSphere ESXi

Issue/Introduction

VMware Cloud Foundation (VCF) workload domain cluster upgrades fail during pre-check validation or host update stages. The failure accompanies a degraded VMware vSAN health status, host network redundancy loss, and physical network adapter (vmnic) link-down states on ESXi hosts.

Symptoms

  • Upgrade pre-check fails with the following error:

Health Check for '' failed, Software compatibility cannot be determined for release 9.0.1.0.24957456, 9.0.2.0.25148086. It can be either a security patch or an out-of-date compatibility data bundle having timestamp 2025-01-21T16:14:55.181000. Firstly, please ensure the software compatibility data bundle is up-to-date. Please note that no software compatibility checks are performed on security patches., Software compatibility cannot be determined for release 8.0.3-3.79.24859861, 9.0.1.0.24957456. It can be either a security patch or an out-of-date compatibility data bundle having timestamp 2025-01-21T16:14:55.181000. Firstly, please ensure the software compatibility data bundle is up-to-date. Please note that no software compatibility checks are performed on security patches., Failed Hosts are: host-1041 Skipped Hosts are: host-1028.host-1038,host-1026.host-1036,host-1024.host-1034,host-1032,host- 1020,host-1030
  • vSAN health displays as degraded in vSphere Client.

  • Network redundancy loss events trigger for affected ESXi hosts.

  • One physical NIC reports Down in ESXi while appearing healthy in Out-of-Band management interfaces (iLO/iDRAC).

  • Examining /var/run/log/vobd.log reveals uplink failure events:
2026-03-13T23:44:58.234Z In (14)vobd [2098167] :[netCorrelator]24158432392us: [vob.net.dvport. uplink. transition. down]Uplink:vmnic#### is down. Affected dvPort: 85 #### 92. 1 uplinks up. Failed criteria: 128

2026-03-13T23:44:58.235Z In(14)vobd [2098167] :[netCorrelator] 24158434167us: [vob.net. vmnic. linkstate.down] vmnic vmnic#### linkstate down

Environment

  • VMware Cloud Foundation 5.x / 9.x

  • VMware vSAN 8.x / 9.x

  • VMware ESXi 8.x / 9.x

Cause

A physical network adapter (vmnic) assigned to the vSAN VMkernel interface experiences a hardware or physical link-down state. Loss of uplink redundancy degrades vSAN health and interrupts the VCF upgrade workflow.

Resolution

  1. Identify the affected host and failed physical interface:

    esxcli network nic list

    Example output:

    Name    PCI Device    Driver  Admin Status  Link Status  Speed  Duplex  MAC Address        MTU
    vmnic1  0000:c0:00.1  icen    Down          Down             0  Half    6c:####:81         9000
  2. Verify physical cable connections, SFP transceiver modules, and top-of-rack (ToR) switch port status for the affected vmnic.

  3. Bring the physical interface administratively up if disabled:

    esxcli network nic up -n vmnic####
  4. If the link state remains down, engage the hardware vendor and network infrastructure team to replace faulty physical components or restore switch port connectivity.

  5. Once vmnic#### reports Up status, verify vSAN health status returns to Green in vSphere Client.

  6. Retry the VCF cluster upgrade pre-check and resume the upgrade workflow.

Additional Information

Network adapter (vmnic) is down or fails with a Failed Criteria Code