End user encounters test recovery plan issues after upgrading Site Recovery Manager
Error observed -
"Failed to recover datastore ####'. VMFS volume residing on recovered devices '"####"' cannot be found. Recovered device '####' not found after HBA rescan. Some virtual machines in the protection group '####' could not be recovered"
Live Recovery Manager 9.0.2
Delete and create the array pair in the following order:
1. Delete recovery plan
2. Delete protection group
3. Delete array pair
4. Create array pair
5. Create protection group
6. Create recovery plan
Note that when deleting or creating the objects, they should be deleted/created on both sites and this should be done automatically by VLSR.
Use the impex tool to take backup of configuration then delete all RP/PG followed by array pair.
Use impex tool to restore configuration which will recreate array pair as new.