Real-Time Alerts Not Triggering for Certain vCenter Logs (Events/Tasks)
search cancel

Real-Time Alerts Not Triggering for Certain vCenter Logs (Events/Tasks)

book

Article ID: 433519

calendar_today

Updated On:

Products

VCF Operations/Automation (formerly VMware Aria Suite) VMware vSphere ESXi

Issue/Introduction

For certain types of vCenter (VC) logs, the alert condition may not be met when using Real Time alerting.

Environment

Aria Operations for Logs: 8.18.x

Resolution

Use Custom Time Period instead of Real Time for alert queries that depend on vCenter events or tasks.
Using a custom time window (e.g., last 5 minutes) ensures that logs ingested with a delay are still evaluated within the alert run, so alert hits are not skipped.

 Explanation of Real-Time Alerting

Real-time alerts in Aria Operations for Logs run on a fixed schedule—every 1 minute by default. Whether a log is evaluated by the alert depends on when it is ingested relative to that 1-minute alert run.

- Logs streaming via Syslog are ingested without meaningful delay. They are available in the system shortly after they occur and are typically evaluated in the next alert run. The alert condition is met as expected.

- vCenter events and tasks are pulled by Operations for Logs, not pushed in real time. By default, these are collected and ingested with a 2-minute interval. So there is an inherent delay between when the event occurs and when it appears in the dataset.

Because real-time alerts run every 1 minute while vCenter events/tasks are pulled every 2 minutes, the following can happen:

1. An alert run executes and evaluates the data currently in the system.
2. The corresponding vCenter event or task has not yet been pulled and ingested (it will arrive in the next 2-minute pull).
3. The alert run completes without that log, so the condition is not met and the alert does not trigger.
4. When the next alert run happens, the time window used for “real time” may no longer include the newly ingested log, so the alert hit can be skipped.

Additional Information

Reference Document:
Define an Alert
Add an Alert to Send Notifications to VMware Aria Operations