Job IZUD02UZ Fails with RC=12 with the following error messages.

GIM36600S ** ALLOCATION FAILED FOR THE ####.###.######.AB0VDATV.# DATA SET USING THE SYSUT2 DDNAME - IKJ56893I DATA SET        
             ####.###.######.AB0VDATV.# NOT ALLOCATED+                                                                         
GIM36600S ** ALLOCATION FAILED FOR THE ####.###.######.AB0VDATV.# DATA SET USING THE SYSUT2 DDNAME - IGD01011I DATA SET        
             ALLOCATION REQUEST FAILED -                                                                                       
GIM36600S ** ALLOCATION FAILED FOR THE ####.###.######.AB0VDATV.# DATA SET USING THE SYSUT2 DDNAME - ACS STORCLAS              
             ROUTINE RETURNED SCMSPS                                                                                           
GIM36600S ** ALLOCATION FAILED FOR THE ####.###.######.AB0VDATV.# DATA SET USING THE SYSUT2 DDNAME - WHICH DOES NOT            
             EXIST                                                                                                             
GIM47800S ** AN ERROR OCCURRED WHILE GIMUNZIP WAS PROCESSING ARCHIVE ######.CAI.PORTPKG.TPX055.GA.AB0VDATV.                    
GIM20501I    GIMUNZIP PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 12.                                          

Environment

z/OSMF 

TPX - Session Management

Cause

The ACS routine is trying to allocate the dataset to STORCLAS = ######, however the storage class ###### is not defined in SMS.  

Resolution