CA Verify for CICS release 9.0 install RECEIVE fails with HLQ SMPETEMP dataset not found.
search cancel

CA Verify for CICS release 9.0 install RECEIVE fails with HLQ SMPETEMP dataset not found.

book

Article ID: 43309

calendar_today

Updated On:

Products

Verify

Issue/Introduction

When doing a base install of CA Verify for CICS release r 9.0. The RECEIVE step fails with DATA SET SMPETEMP.CEQC900.F1 NOT ALLOCATED.  A Dataset with an HLQ of SMPETEMP is failing when it is dynamically allocated.  

Environment

CICS

Cause

During the RECEIVE processing CA Verify for CICS datasets are dynamically allocated by SMPE as part of the receive process. In this case dataset SMPETEMP.CEQC900.F1 was being dynamically allocated. Since the SMPETEMP HLQ was not a valid HLQ  on the LPAR, the user received a dynamic allocation failure and the receive job ended with a return code of 12. The following messages are displayed:

12:17:33 IGD17102I CATALOG ERROR IN DEFINING NONVSAM DATA SET

12:17:33 SMPETEMP.CEQC900.F1

Resolution

Review the CA Verify for CICS install JCL member ELT3CSI. JCL member ELT3CSI allocates the SMPCSI dataset and sets up the SMP environment. In this member do a find for DSPREFIX. The DSPREFIX parameter should be set to a valid HLQ on your LPAR. The DSPREFIX value (HLQ) is used by SMPE to dynamically allocate the SMP/E datasets required to receive the product. The default setting for DSPREFIX is DSPREFIX(SMPETEMP).

The DSPREFIX can be updated by using the TSO ISPF SMP/E PRIMARY OPTION MENU.