nsx01> get managers注:NSX 4.2より前のバージョンでは、ノード自体への接続は常に「スタンバイ」状態です。他のノードにも注意してください。
<Date> UTC <Time>
- <IP address of Manager 1> Standby (NSX-RPC)
- <IP address of Manager 2> Connected (NSX-RPC)*
- <IP address of Manager 3> Standby (NSX-RPC)
<Timestamp> <Hostname> NSX 1812 - [nsx@6876 comp="nsx-manager" subcomp="appl-proxy" s2comp="nsx-net" tid="1846" level="INFO"] StreamSocket[1276822 Init f:-1 i:-1 ssl://0.0.0.0:1234 <- ?] Created
<Timestamp> <Hostname> NSX 1812 - [nsx@6876 comp="nsx-manager" subcomp="appl-proxy" s2comp="nsx-net" tid="1846" level="WARNING"] Certificate validation: couldn't find SHA256 digest '<SHA256 digest of the APH-TN certificate of another Manager node>' in local trust store
<Timestamp> <Hostname> NSX 1812 - [nsx@6876 comp="nsx-manager" subcomp="appl-proxy" s2comp="nsx-net" tid="1846" level="ERROR" errorCode="NET1111"] Certificate validation failed: 18-self signed certificate#012Certificate:#012 Data:#012 Version: 3 (0x2)#012 Serial Number: <Serial number of the certificate> #012 Signature Algorithm: sha256WithRSAEncryption#012 Issuer: CN=VMware-NSX-ApplProxyHub; O=VMware Inc.; L=Palo Alto; ST=California; C=US#012 <snip>
<Timestamp> <Hostname> NSX 1812 - [nsx@6876 comp="nsx-manager" subcomp="appl-proxy" s2comp="nsx-net" tid="1846" level="ERROR" errorCode="NET4"] NetTransport[1] Accept on endpoint 'ssl://0.0.0.0:1234' failed with error 336105606-certificate verify failed
<Timestamp> <Hostname> NSX 1812 - [nsx@6876 comp="nsx-manager" subcomp="appl-proxy" s2comp="nsx-rpc" tid="1846" level="WARNING"] RpcTransport[1] Accept on 'ssl://0.0.0.0:1234' failed with error 336105606-certificate verify failed
<Timestamp> <Hostname> NSX 1812 - [nsx@6876 comp="nsx-manager" subcomp="appl-proxy" s2comp="nsx-net" tid="1846" level="INFO"] StreamConnection[1276821 Closing on ssl://0.0.0.0:1234 sid:1276821] Closing (reason: network error)
<Timestamp> <Hostname> NSX 1812 - [nsx@6876 comp="nsx-manager" subcomp="appl-proxy" s2comp="nsx-net" tid="1846" level="INFO"] StreamConnection[1276821 Closed on ssl://0.0.0.0:1234 sid:-1] Closed (reason: network error, error: 0-Success)
<Timestamp> <Hostname> NSX 1812 - [nsx@6876 comp="nsx-manager" subcomp="appl-proxy" s2comp="nsx-net" tid="1846" level="INFO"] StreamConnection[1276821 Deleted on ssl://0.0.0.0:1234 sid:-1] Pending callback count [0]
<Timestamp> <Hostname> NSX 1812 - [nsx@6876 comp="nsx-manager" subcomp="appl-proxy" s2comp="nsx-net" tid="1846" level="INFO"] StreamSocket[1276821 Closing f:62 i:508046837 ssl://0.0.0.0:1234 <- <IP address of another Manager node>:37220] DoClose
VMware NSX 4.1.x
VMware NSX 4.2.x
各ノードの APH-TN 証明書と APH-AR 証明書のサブジェクトは一意である必要があります。
複数の証明書が同じサブジェクトを持つ場合、信頼できるのは 1 つの証明書のみであり、証明書の検証に失敗したために他のノードからの接続は拒否されます。
APH-TN 証明書と APH-AR 証明書のsubjectが一意であることを確認してください。
root@nsx01:~# cat /etc/vmware/nsx-appl-proxy/appl-proxy-public-cfg.json
{ "uuid" : "53####25-a##1-4##2-b##e-############" }
VMware-NSX-ApplProxyHub/UID=<手順 1 で取得した UUID。