Issue/Introduction

  • After ENS port is disabled and vmxnet3 detached from ENS, repeated logs of "NetPort 708: Failed to acquire port non-exclusive lock" is observed 
  • Impact: Packet loss, edge_nic_out_of_transmit_buffer (overflow >86% with ring size 4096), BFD/BGP flapping, tunnel instability.
  • Vmxnet3: "Hang detected" on Edge VM interfaces 
  • ESX host experiences PSOD with error "#PF Exception 14".

Environment

ESXi 8.0.3 build 24784735

NSX 4.2.1.4

Cause

A memory leak in the Enhanced Dataplane causes intermittent connectivity failures when an NSX Edge VM and workload VMs share the same ESXi host.

Resolution

The internal memory leak issues are fixed in below NSX releases. Upgrade NSX to at least a version listed below.