During a Reprotect operation in VMware Site Recovery Manager (SRM), the workflow fails during the "Synchronize Storage" phase.
SRM UI displays error: Failed to sync data on replica consistency group '<CG_NAME>'. The 'Sync Once' operation failed. Please retry the workflow.
vmware-dr.log contains: dr.storageProvider.fault.StorageDeviceGroupSyncFailed.
HPE Storage Replication Adapter (SRA) logs show a 400 Bad Request with the following specific error: HPESRA: Failed to synchronize remotecopygroup <CG_NAME> even after retries and received error Error: Group <CG_NAME>'s target <TARGET_ID> is already involved in a synchronization.
VMware Live Site Recovery 9.x
400 Bad Request[2026-02-24 13:08:25.478 UTC] [INFO] HPESRA: Put response status is :: 400 Bad Request[2026-02-24 13:08:25.480 UTC] [INFO] HPESRA: Failed to synchronize remotecopygroup DR_xxxxxxx_xxRD even after retries and received error Error: Group DR_xxxxxx_xxRD's target ITxxxxxxSA001 is already involved in a synchronizationThis is typically a transient condition. Follow these steps to resolve:
Monitor Array Status: Log into the HPE Storage Management Console (SSMC) or CLI.
Verify RCG State: Ensure the Remote Copy Group (RCG) mentioned in the error is in a Synced or Consistent state.
Check for Active Tasks: Confirm that no manual synchronization or maintenance tasks are actively running on the array for this RCG.
Retry Reprotect: Once the array reports the RCG is idle and healthy, return to the SRM UI and click Retry on the failed Reprotect task. The workflow will resume from the last successful checkpoint.