DDRTVD0006 DSF STRUCTURE CATALOG ERROR DDD-014
search cancel

DDRTVD0006 DSF STRUCTURE CATALOG ERROR DDD-014

book

Article ID: 430308

calendar_today

Updated On:

Products

Datacom Datacom/AD CA 7 Workload Automation

Issue/Introduction

RTVCAT step of AL2DCA30 job is getting the error.

As part of upgrading CA 7 from version 11.3 to 12.1, we ran AL2DCA10, AL2DCA20, AL2DCA30 - all these jobs ran successfully with RC 0. But AL2DCA40 started producing abend and eventually it made datacom MUF abend at SOC4.

 

 

 

 

 

Cause

 

 

 

 

 

 

Resolution

Make sure the latest Datacom/AD maintenance has been applied, and then rerun AXNEW01 job (as indicated in the Datacom/AD 15.1 documentation) to initialize all Datacom system files including the datadictionary. Then rerun the CA7 jobs starting with AL2DCA05. 

Additional Information

Make sure JOBRC=(LASTRC) parameter is in the job statement in order to be notified that the job ended with RC 0. It would look something like this:

$HASP165 AXNEW01  ENDED AT sysname  - JOBRC=0000 CN(INTERNAL)

Otherwise, the Job could run successfully and produce a final Job Return Code of 0001 or 0002.