Adding IPMI/iLO settings for host power management does not work on MiTAC servers with MegaRAC OneTree reporting the error:
Operation failed! A specified parameter was not correct: ipmiInfo
BMC settings and credentials have been validated and the error persists.
Impact:
R2513G6 and R2520G6 with Intel Xeon 6 6500P/6700P (Granite Rapids-SP).vSphere 9.0
vSphere 8.x
vSphere 7.x
To power off/on MiTAC servers remotely, use ipmitool 1.8.19 or newer, MegaRAC OneTree web interface, or other remote management options provided by MiTAC.
The ESXi host can also be shut down using the vSphere Client via Host->Power->Shut down.
Use remote management methods provided by MiTAC to enter/exit host power saving mode as required.