Intel E810/E822 Network Adapters remain offline after ESXi 8.x upgrade with "ICE_ERR_AQ_ERROR"
search cancel

Intel E810/E822 Network Adapters remain offline after ESXi 8.x upgrade with "ICE_ERR_AQ_ERROR"

book

Article ID: 429905

calendar_today

Updated On:

Products

VMware vSphere ESXi

Issue/Introduction

After upgrading ESXi hosts to version 8.x, physical network adapters using the icen driver (Intel Ethernet 800 Series) may remain in an offline state. Network connectivity is not restored until the adapter is physically reseated, manually re-enabled, or the host is rebooted.

Analysis of the vmkernel.log reveals repeated link up/down events. Notably, there are no "Failure Criteria 128" messages, which would otherwise indicate a hard hardware failure.

Instead, the following errors appear, indicating initialization failures in the Admin Queue (AQ):

2026-01-21T16:13:26.188Z Wa(180) vmkwarning: cpu68:2097934)WARNING: icen: icen_InitPhyUserCfg:2218: 0000:99:00.0: Failed to get PHY software configuration, Error: ICE_ERR_AQ_ERROR
2026-01-21T16:13:26.188Z Wa(180) vmkwarning: cpu68:2097934)WARNING: icen: icen_ForcePhyLinkState:495: 0000:99:00.0: Failed to get phy capabilities - Error: ICE_ERR_AQ_ERROR
2026-01-21T16:13:26.188Z Wa(180) vmkwarning: cpu68:2097934)WARNING: icen: icen_InitHW:2648: 0000:99:00.0: Failed to force phy up, Status: I/O error
2026-01-21T16:13:26.188Z Wa(180) vmkwarning: cpu68:2097934)WARNING: icen: icen_SetFc:2507: 0000:99:00.0: Failed to set Flow Control configuration, Error: ICE_ERR_AQ_ERROR
2026-01-21T16:13:26.188Z Wa(180) vmkwarning: cpu68:2097934)WARNING: icen: icen_SetFc:2512: 0000:99:00.0: Failed to set flow control. Unable to get phy capabilities, aq_err 14

 

Environment

  • VMware ESXi 8.x
  • Intel Ethernet 800 Series Adapters (E810 / E822)
  • icen native driver

Cause

This issue is caused by a firmware incompatibility. The firmware version currently installed on the network adapter is higher than the version validated and listed on the VMware Hardware Compatibility List (HCL) for the specific ESXi 8.x release.

The ICE_ERR_AQ_ERROR indicates that the driver sent a command to the device's firmware via the Admin Queue, but the firmware failed to execute it properly. This mismatch prevents the driver from retrieving PHY capabilities or setting flow control, resulting in the interface staying down.

 

Resolution

To resolve this issue, ensure the firmware and driver combination matches the VMware Compatibility Guide.

  1. Identify the current firmware version and driver version on the host: esxcli network nic get -n vmnicX

  2. Consult the VMware Hardware Compatibility List (HCL) for the specific IO device.

  3. If the installed firmware is newer than the supported version listed on the HCL, contact the hardware vendor to:

    • Confirm if a newer driver is available that supports the higher firmware.

    • Obtain tools/procedures to downgrade the firmware to the supported version listed on the HCL.

 

Additional Information

The error aq_err 14 corresponds to an internal Admin Queue error where the firmware rejected the opcode sent by the driver due to a version or capability mismatch.