Edge Node Shows Degraded Status with pNIC Down After NSX Upgrade
search cancel

Edge Node Shows Degraded Status with pNIC Down After NSX Upgrade

book

Article ID: 429896

calendar_today

Updated On:

Products

VMware NSX VMware vSphere ESXi

Issue/Introduction

After upgrading NSX, an Edge node may display Degraded status and report pNIC Down in NSX Manager immediately after exiting maintenance mode.

Symptoms

  • Edge node shows Degraded status after upgrade.
  • pNIC status appears as DOWN in NSX Manager.
  • Edge was active on Tier-0 gateway at time of occurrence.
  • No physical network failure observed.
  • Degraded alarm clears after manually placing the Edge into maintenance mode and exiting.

 

Environment

VMware NSX

Cause

During Edge upgrade, the node enters maintenance mode and datapath services are temporarily withdrawn.

After the Edge exits maintenance mode:

  • Host configuration synchronization occurs.
  • Datapath objects are recreated.
  • Uplink devices are re-added.
  • VTEP and logical switch bindings are reprogrammed.

A temporary synchronization delay between datapath readiness and management-plane reporting may cause NSX Manager to show pNIC Down and Degraded state.

Resolution

No infrastructure or hardware remediation is required.

The condition resolves automatically once datapath realization completes.

If the Degraded state persists beyond expected convergence time perform below workaround:

  1. Place the affected Edge into maintenance mode.
  2. Exit maintenance mode.
  3. Confirm uplink interfaces transition to UP state.
  4. Verify Edge health returns to Normal.