Q: What does the 'Client cluster mount check' check do?
- This check is to verify if there is a client cluster mounting the datastore of the vSAN cyber recovery cluster.
Q: What does it mean when it is in an error state?
- If this test returns red, it means there is no client cluster configured for the vSAN cyber recovery cluster.
Note: vSAN cyber recovery won’t work without a client cluster configured, which is needed to run VMs during recovery.
Q: How does one troubleshoot and fix the error state?
- To address this error, configure a client cluster mounting the datastore of the vSAN cyber recovery cluster with the following steps:
-
- Prepare a vSAN HCI cluster or vSAN compute cluster as the client cluster for this vSAN cyber recovery cluster.
- Navigate to the client cluster's Configure tab, select vSAN > Datastore Management.
- Click 'Mount Remote Datastore', select the datastore of the vSAN cyber recovery cluster, and then complete the mounting process.