Error: "Failed to load NSX Cluster from the Inventory" during Brownfield vCenter Import in VCF 9.x
search cancel

Error: "Failed to load NSX Cluster from the Inventory" during Brownfield vCenter Import in VCF 9.x

book

Article ID: 429414

calendar_today

Updated On:

Products

VCF Operations/Automation (formerly VMware Aria Suite)

Issue/Introduction

During a VMware Cloud Foundation (VCF) brownfield import, the workflow fails at the step "Import provided infrastructure into SDDC Manager as a workload domain" with the following message:

Import operation for import with id <UUID> failed internally. Command was python3 /opt/vmware/vcf/domainmanager/scripts/vcf-import-tool/vcf_brownfield.py import --skip-ssh-thumbprint-validation --sso-user [email protected] --domain-name wld-prod --vcenter <FQDN> --internal-vcf-auth --nsx-fqdn <FQDN> --output-dir /var/log/vmware/vcf/domainmanager/brownfield/<UUID>/ --non-interactive. Please check the log files located in /var/log/vmware/vcf/domainmanager/brownfield/<UUID>/ on the SDDC Manager appliance

This issue occurs under the following conditions:

  • The NSX-T Cluster is shared with another VI workload domain that has already been successfully imported.
  • The FQDN of the NSX-T Manager is configured using mixed-case or upper-case characters.

The following error will be observed in /var/log/vmware/vcf/domainmanager/domainmanager.log:

[YYYY-MM-DD HH:mm:ss,000] [ERROR] import_domain:230: An error occured while marking NSXT Clusters as ACTIVE
Traceback (most recent call last):
  File "/opt/vmware/vcf/domainmanager/scripts/vcf-import-tool/domain_import/import_domain.py", line 228, in import_domain_in_sddc_manager

Environment

VMware Cloud Foundation 9.x

Cause

The import script logic performs a case-sensitive string comparison between the provided FQDN in the import specification and the FQDN registered within the NSX Manager inventory.

If there is a case mismatch (e.g., nsx-t.example.com vs. Nsx-T.example.com), the validation fails to identify the existing NSX cluster.

Resolution

This issue will be resolved in future version of VCF 9.x.