Intermittent connectivity loss to the BGP.
search cancel

Intermittent connectivity loss to the BGP.

book

Article ID: 429295

calendar_today

Updated On:

Products

VMware NSX VMware vSphere ESXi

Issue/Introduction

  • Intermittent BGP link flaps were observed.
  • The frr.log shows the BGP peer transitioning to a down state.
  • Validate the vmnic statistics for the hashed Edge uplinks that are reporting a high "receive packets dropped" value.
  • Bandwidth utilization should be validated on the vmnics connected to the DVS. Only two uplinks are currently in use, carrying Host Management, vMotion, vSAN, VM, and Edge traffic.

Environment

VMware NSX

Cause

High bandwidth utilization on the uplinks resulted in a high receive-packet drop count, leading to packet loss and BGP flaps.

Resolution

  • Add additional uplinks to the DVS to increase bandwidth and reduce uplink congestion.
  • Add the uplinks to the default teaming policy in the uplink profile to utilize the additional bandwidth.
    Navigate to NSX UI → System → Profiles → Uplink Profiles, edit the required uplink profile, update the teaming policy, and add the additional uplinks to the Default Teaming.