Symptoms:
/var/log/vobd.log では、ディスクが永続的なエラー状態にあることが報告されます。YYYY-MM-DDTHH:MM:SSZ:[vSANCorrelator] 12219239351514u3:[esx.problem. vob. vsan.pdl. offline] vSAN device ########-####-####-####-########### has gone offline.YYYY-MM-DDTHH:MM:SSZ:[vSANCorrelator] 12219239351514u3:[esx.problem. vob. vsan. lsom. devicerepair] Device e ########-####-####-####-########### is in offline state and is getting repaired.YYYY-MM-DDTHH:MM:SSZ:[vSANCorrelator] 12219239351514u3:[vob.vsan.pdl.offline] vSAN device e ########-####-####-####-########### has gone offline.YYYY-MM-DDTHH:MM:SSZ:[vSANCorrelator] 12219239351514u3:[esx.problem. vob.vsan.pdl.offline] vSAN device e ########-####-####-####-########### has gone offline.YYYY-MM-DDTHH:MM:SSZ:[vSANCorrelator] 12219239351514u3:[vob. vsan.lsom. diskerror] vSAN device e ########-####-####-####-########### is under permanent error.(または)
YYYY-MM-DDTHH:MM:SSZ In(14) vobd[2098148]: [vSANCorrelator] 9883129325851us: [vob.vsan.pdl.offline] vSAN device 5####3c-#####5##d-d####3-######1 has gone offline.YYYY-MM-DDTHH:MM:SSZ In(14) vobd[2098148]: [APDCorrelator] 9882990619157us: [esx.problem.storage.apd.start] Device or filesystem with identifier [##########] has entered the All Paths Down state.YYYY-MM-DDTHH:MM:SSZ In(14) vobd[2098148]: [vSANCorrelator] 9882990619196us: [esx.problem.vob.vsan.pdl.offline] vSAN device 5####c-1626-####-####-f01#####1 has gone offline.YYYY-MM-DDTHH:MM:SSZ In(14) vobd[2098148]: [psastorCorrelator] 9882990619971us: [esx.problem.storage.connectivity.lost] Lost connectivity to storage device #############. Path vmhba0:C0:T0:L0 is down. Affected datastores: Unknown.YYYY-MM-DDTHH:MM:SSZ In(14) vobd[2098148]: [psastorCorrelator] 9883129325791us: [vob.psastor.device.state.permanentloss] Device :eui.############ has been removed or is permanently inaccessible.YYYY-MM-DDTHH:MM:SSZ In(14) vobd[2098148]: [psastorCorrelator] 9882990620278us: [esx.problem.psastor.device.state.permanentloss] Device: eui.############### has been removed or is permanently inaccessible. Affected datastores (if any): Unknown.VMware vSAN 7.x
VMware vSAN 8.x
これはディスク(ストレージデバイス)の問題が原因で発生します。
vSAN は、I/O 障害が発生するとディスクをオフラインとしてマークし、影響を受けるディスクでのそれ以上の操作を防止します。
ディスク(ストレージデバイス)が存在し、永続的なエラーが発生している場合は、コントローラーのドライバー/ファームウェアにも問題がある可能性があります。ハードウェアの互換性を確認し、適切なドライバー/ファームウェアを適用してください。
該当のディスクで継続して問題が発生する場合は、ハードウェア ベンダーに依頼してディスクの状態を確認し、次の手順を実施します。