Wrong VLAN for Host TEP Interfaces Set During VCF Deployment
book
Article ID: 428096
calendar_today
Updated On:
Products
VMware NSXVMware SDDC Manager / VCF Installer
Issue/Introduction
During VCF Management Domain deployment the wrong TEP VLAN was set for ESXi host uplinks
The VLAN used for the ESXi host TEP interfaces needs to be changed
Environment
VMware NSX
VMware SDDC Manager
Resolution
SDDC Manager does not store the VLAN configuration for TEP connections. No changes need to be made within SDDC Manager.
To change the VLAN ID used on a Host Uplink Profile, navigate to System > Fabric > Profiles > Uplink Profiles and click the 3 dots to the right of the Uplink Profile and select Edit. After changing the Transport VLAN, click Save. The VLAN change will occur once the Uplink Profile is saved.