PSOD (#PF Exception 14 in world ###:fdsAIO IP 0x############ addr 0x###) occurs in an ESXi 7.0 environment
search cancel

PSOD (#PF Exception 14 in world ###:fdsAIO IP 0x############ addr 0x###) occurs in an ESXi 7.0 environment

book

Article ID: 427973

calendar_today

Updated On:

Products

VMware vSphere ESXi

Issue/Introduction

  • An ESXi host becomes unresponsive and displays a Purple Screen of Diagnostics (PSOD)
  • PSOD console displays an error message similar to the following:
    #PF Exception 14 in world ###:fdsAIO IP 0x########## addr ###
  • The backtrace on the PSOD screen includes the following functions:
    Fil3ExtendHelperVMFS6
    Fil3_SetFileLengthVMFS6
    Note: Additional functions may appear below these entries.

Environment

VMware vSphere ESXi 7.x

Cause

This issue occurs when a heap allocation fails during a file system extension operation, leading to an "Out of Memory" (OOM) condition. A fatal Page Fault (PF) exception is triggered because this OOM state is not handled correctly.

Resolution

This issue is resolved in vSphere ESXi 7.0 Update 2.