vSAN Witness node partitioned.
vSAN objects are in "Reduced availability" state.
Ports 12321 and 2233 are open between the vSAN witness node and the vSAN data nodes.
esxcli vsan cluster getCluster Information: Enabled: true . . Sub-Cluster Membership Entry Revision: 50762 .VMware vSAN 8.x (Stretched Cluster)
Network packet drops or latency between the vSAN data nodes and the witness node causes witness component creation failures.
These failures build up discarded component (DC) entries, which consume the CMMDS arena memory on the witness node, leading to exhaustion and preventing the witness from joining the cluster.
The latency between vSAN witness host and leader node can be validated from vSAN leader node's /var/run/log/vmkernel.log:
2025-12-16T09:12:37.088Z In(182) vmkernel: cpu0:2098316)CMMDS: LeaderUpdateMeanRTLatency:12423: Throttled: <vSAN_cluster_UUID>: High RT latency. Node <vSAN_witness_UUID>, RT latency 580(ms). Mean RT latency 193(ms)
The vSAN witness node failure to join the cluster can be validated as per below:
vSAN witness first updates it's unicastagent table with information about all vSAN nodes in the cluster (from witness host /var/rung/log/vmkernel.log):
2025-12-16T04:05:30.492Z In(182) vmkernel: cpu0:588843)CMMDSNet: CMMDSNetCreateUnicastPath:748: <vSAN _cluster_uuid>: Created unicast path ##.##.##.##;12321 for <vSAN_node_uuid>.2025-12-16T04:05:30.692Z In(182) vmkernel: cpu0:588843)CMMDSNet: CMMDSNetCreateUnicastPath:748: <vSAN _cluster_uuid>: Created unicast path ##.##.##.##;12321 for <vSAN_node_uuid>Post, this vSAN witness node update's its vSAN leader information from "None" to the UUID of the vSAN leader node. It then requests a snapshot from the leader node to re-join the vSAN cluster (from witness host /var/rung/log/vmkernel.log):
This snapshot request is for information regarding the component deletion and discarded component entries.
2025-12-16T04:05:31.369Z In(182) vmkernel: cpu0:588843)CMMDS: CMMDSLogStateTransition:1838: <vSAN_cluster_UUID>: Transitioning(<vSAN_witness_uuid>) from Standalone to Rejoin: (Reason: Found a preferred leader node).2025-12-16T04:05:31.369Z In(182) vmkernel: cpu0:588843)CMMDSNet: CMMDSNet_SetLeader:1330: <vSAN_cluster_UUID>: Updating leader node: old=none new=<vSAN_leader_uuid>.2025-12-16T04:05:31.369Z In(182) vmkernel: cpu0:588843)CMMDS: CMMDSAgentlikeSetMembership:551: <vSAN_cluster_UUID>: Setting new membership uuid ########-####-####-####-############.2025-12-16T04:05:32.390Z In(182) vmkernel: cpu0:588843)CMMDS: RejoinRequestSnapshotWork:993: <vSAN_cluster_UUID>: Send a snapshot request to leader successfully.Next, this snapshot request is received by the vSAN leader node and it sends back the requested snapshot to the witness node (from vSAN leader node /var/rung/log/vmkernel.log):
2025-12-16T04:05:32.390Z In(182) vmkernel: cpu7:2098316)CMMDS: LeaderRxSnapshotRequest:4447: <vSAN_cluster_UUID>: Received a snapshot request from node <vSAN_witness_uuid>2025-12-16T04:05:32.390Z In(182) vmkernel: cpu7:2098316)CMMDS: LeaderInitiateRejoinSnapshot:4141: <vSAN_cluster_UUID>: Allocating snapshot workblock for node <vSAN_witness_uuid>2025-12-16T04:05:32.706Z In(182) vmkernel: cpu11:2098316)CMMDS: LeaderSendSnapshotUpdateWork:3930: <vSAN_cluster_UUID>: Done sending snapshot to node <vSAN_witness_uuid>On the witness node it can be seen that it fails to allocate arena space for the snapshot due to arena memory exhaustion and then transitions back to standalone node (from witness host /var/run/log/vmkernel.log):
2025-12-16T04:05:35.752Z In(182) vmkernel: cpu0:588843)CMMDS: RejoinBuildSnapshotEntry:2528: <vSAN_cluster_UUID>: Failed to allocate arena space for snapshot2025-12-16T04:05:35.752Z In(182) vmkernel: cpu0:588843)CMMDS: CMMDSLogStateTransition:1838: <vSAN_cluster_UUID>: Transitioning(<vSAN_witness_UUID>) from Rejoin to Standalone: (Reason: Arena memory exhausted)On the leader node it can be seen that there is failure in receiving the sent snapshot and due to this it removes the witness node from the vSAN cluster membership (from vSAN leader node /var/rung/log/vmkernel.log):
2025-12-16T04:05:35.752Z In(182) vmkernel: cpu12:2098316)CMMDS: CMMDSStateMachineReceiveLoop:1654: <vSAN_cluster_UUID>: Error receiving from <vSAN_witness_UUID>: Failure2025-12-16T04:05:35.752Z In(182) vmkernel: cpu12:2098316)CMMDS: CMMDSStateDestroyNode:708: <vSAN_cluster_UUID>: Destroying node <vSAN_witness_UUID>: Failed to receive from nodeThe above 5 operations occur every ~5 seconds, due to which it the vSAN membership entry revision count keeps increasing.
The cause of this issue is due to the EPD service not being able to clear up the discarded components and causes CMMDS Arena resources to become exhausted and CMMDS (membership) service to become unstable.
From the vSAN data nodes, the number of discarded components can be checked by running the below command:
grep "\"type\":" cmmds-tool_find--f-python.txt | sort | uniq -c410 "type": "DISCARDED_COMPONENTS",The EPD service was not able to clear up the discarded components and keeps restarting due to memory allocation failures.
(From vSAN data node's /var/run/log/vmkernel.log)2025-12-19T02:30:59.050Z In(182) vmkernel: cpu12:18069188)Admission failure in path: host/opt/vsan/epd:epd.18069188:uw.18069188
Although the number of discarded component entries may be few, the number of witness component entry for each discarded component entry kept increasing.
Network latency and packet loss between the vSAN leader node and the witness led to repeated witness component creation failures. This caused witness component entries to accumulate for each discarded component, eventually exhausting CMMDS Arena memory.
To resolve this issue:
Investigate and fix the external network which connects the vSAN witness to the two vSAN data nodes which is causing the latency and packet drops.
Clean the discarded component entries. This would still fill up again if the network issue is not resolved.
SSH to all hosts in the vSAN cluster.
Stop the epd service on all hosts (except the witness node) using the command: /etc/init.d/epd stop
(epd service does not run on the witness node)
Verify that the epd service is stopped on all hosts: /etc/init.d/epd status
Copy the existing epd database (on all hosts except the witness) incase it is required for further troubleshooting: cp /scratch/epd-storeV2.db /scratch/epd-storeV2-copy1.db
Delete the existing epd database (on all hosts except the witness): rm -f /scratch/epd-storeV2.db
Run the following commands on one of the vSAN data nodes:
Delete the DC entries from CMMDS: cmmds-tool delete -t DISCARDED_COMPONENTS
Verify that DC entries are deleted: cmmds-tool find -t DISCARDED_COMPONENTS | wc -l
On all hosts, start up the epd service except the witness node: /etc/init.d/epd start
Validate that the epd service is running on all hosts except the witness node: /etc/init.d/epd status
Verify that the witness has joined the vSAN cluster and is not partitioned.