Error "Unexpected PROCEDURE" running AIS7SRVR in CA7 Data Provider
search cancel

Error "Unexpected PROCEDURE" running AIS7SRVR in CA7 Data Provider

book

Article ID: 427151

calendar_today

Updated On:

Products

Automation Analytics & Intelligence

Issue/Introduction

The CA7 AAI Mainframe Data Provider (MDP) task fails with an REXX error during execution. This issue typically occurs after the task successfully recovers previous data or completes a normal event processing cycle, specifically when catching up to the current time. The system displays the following error messages in the task log:

ERROR MESSAGE: "1664 +++ PROCEDURE 785 +++ edttm = CALCENDDTTM(sdttm, ejul||etim, 30) IRX0017I Error running /<install dir>, line 1664: Unexpected PROCEDURE"

 

 

  • Task fails after "WARM mode start" checkpoint

     
  • Error IRX0017I in AIS7SRVR log

     

  • Job ends with RC=3840

 

Environment

 

  • CA 7 Workload Automation

     

  • AAI Mainframe Data Provider 24.2.1

 

Cause

Defect DE181377

Resolution

 

  • DOWNLOAD THE FIX PACKAGE

    Log in to the Broadcom Support Portal and locate the solution for AAI.Mainframe 24.2.2

 

  • INSTALL THE UPGRADE

Apply the AAI.Mainframe 24.2.2 upgrade to your z/OS environment following standard installation procedures for the Data Provider.

 

  • RESTART THE TASK

Restart the CA7AAI task.

 

EXPECTED: The task initializes, catches up on historical data, and continues processing current events without the PROCEDURE error.