When updating a domain / host in SDDC manager you will get an error indicating that the host is incompatible with the Patch Upgrade ISO file
Attempting to upgrade the same host using a baseline in vCenter Update manager will also fail at the remediation stage with a incompatibility error
VCF 5.x
vCenter 7.x , 8.x
The events bellow will be seen in the logs on the SDDC manager
lcm.log
2026-01-22T13:37:51.899+0000 INFO [vcf_lcm,0000000000000000,0000,upgradeId=89aec6b9-7c6a-4929-bf73-8bfd45c35b74,resourceType=ESX_HOST,resourceId=043fe60e-9163-40f5-a9e2-4977771efc95,bundleElementId=a7cbf9f
4-cb00-4fdc-8f8c-fec1c6c7bcb4] [c.v.e.s.c.c.vmware.vum.VumClient,Upgrade-1] Baseline group under verification: (integrity.BaselineGroupInfo) {
dynamicType = null,
dynamicProperty = null,
name = vSAN Cluster 'Management-Cluster',
description = vSAN cluster has ISO(s) from unsupported xxxxxxx, inc..
vum-server.log
2026-01-27T12:18:32.421+01:00 info vmware-vum-server[14160] [Originator@6876 sub=vmomi.soapStub[0]] SOAP request returned HTTP failure; <SSL(<io_obj p:0x00007fb59c17a800, h:34, <TCP 'xxx.x.x.x : xxxxx'>, <TCP 'xxx.x.x.x : xx'>>), /sdk>, method: queryView; code: 500(Internal Server Error); fault: (vim.fault.InvalidName) {
--> faultCause = (vmodl.MethodFault) null,
--> faultMessage = <unset>,
--> name = "UserVars.ImageCachedSystem",
--> entity = <unset>
--> msg = "Received SOAP response fault from [<SSL(<io_obj p:0x00007fb59c17a800, h:34, <TCP 'xxx.x.x.x : xxxxx'>, <TCP 'xxx.x.x.x : xxxxx'>>), /sdk>]: queryView
--> 'UserVars.ImageCachedSystem' is invalid or exceeds the maximum number of characters permitted."
-> <test>
--> <name>HOST_ACCEPTANCE</name>
--> <expected>
--> <value>True</value>
--> </expected>
--> <found>
--> <value>False</value>
--> </found>
--> <result>ERROR</result>
--> </test>
-->
When we look at the host vua logs we will see the values bellow
-> --------
--> stderr: --------
--> /tmp/vuaScript-Nq7Q30/precheck.py:1654: DeprecationWarning: pyvsilib is replaced by vmware.vsi
--> import pyvsilib
--> Acceptance level of the host has to change from accepted to partner to match with the new imageprofile and proceed with upgrade.
-->
--> --------
-->
The issue is that there are vibs in the image that have a different acceptance level then the value set on the host / cluster
For example a vib might have PartnerAccepted as its value but the host might be set to VMwareAccepted
This causes the incompatibility and results in the update failure in both SDDC manager and vCenter Update manager
To review and resolve this use the commands in the techdoc linked bellow to check acceptance level and adjust as required