Stale replicated folders or files at DR site on vSAN datastore causing high utilization - vCenter Server / Ruby vSphere Console
book
Article ID: 426636
calendar_today
Updated On:
Products
VMware vSANVMware Live RecoveryVMware vSphere ESXi
Issue/Introduction
Symptoms:
A capacity discrepancy is observed, where the primary datacenter space utilization is less than the disaster recovery utilization.
The target datastore virtual machine directory is verified to contain replication files, including base disks, delta files (RDID), and HBR configuration files.
Environment
vSphere replication
VMware vSAN
Cause
Orphaned vSAN objects and stale replication metadata remain on the target datastore following incomplete virtual machine removals or replication disruptions.
These inaccessible objects consume datastore capacity because their metadata remains registered in the vSAN object database even after the logical VM is removed from the vCenter inventory.
Resolution
Manual cleanup of the vSAN object database and stale replication metadata is required to reclaim space.