Stale replicated folders or files at DR site on vSAN datastore causing high utilization - vCenter Server / Ruby vSphere Console
search cancel

Stale replicated folders or files at DR site on vSAN datastore causing high utilization - vCenter Server / Ruby vSphere Console

book

Article ID: 426636

calendar_today

Updated On:

Products

VMware vSAN VMware Live Recovery VMware vSphere ESXi

Issue/Introduction

Symptoms:

  • A capacity discrepancy is observed, where the primary datacenter space utilization is less than the disaster recovery utilization.

  • The target datastore virtual machine directory is verified to contain replication files, including base disks, delta files (RDID), and HBR configuration files.

Environment

  • vSphere replication
  • VMware vSAN

Cause

  • Orphaned vSAN objects and stale replication metadata remain on the target datastore following incomplete virtual machine removals or replication disruptions.
  • These inaccessible objects consume datastore capacity because their metadata remains registered in the vSAN object database even after the logical VM is removed from the vCenter inventory.

Resolution

Manual cleanup of the vSAN object database and stale replication metadata is required to reclaim space.

To resolve this issue, contact Broadcom Support.