AXACTUPG Fails RC=12 IEW2470E 9511 ORDERED SECTION DDCLLPR NOT FOUND IN MODULE.
search cancel

AXACTUPG Fails RC=12 IEW2470E 9511 ORDERED SECTION DDCLLPR NOT FOUND IN MODULE.

book

Article ID: 426566

calendar_today

Updated On:

Products

Datacom/AD

Issue/Introduction

The Upgrade Job AXACTUPG job fails with: 

JOB(AXACTUPG) STEP(STEP2E  ) PGM= IEWL      PROCEDURE(LNKSTP  )               
IEW2278I B352 INVOCATION PARAMETERS - LIST,LET,XREF,MAP,NCAL,REUS(SERIAL)    
IEW2322I 1220  1    INCLUDE SYSLIB(DDCLLPR)                                  
 IEW2303E 1030 MEMBER DDCLLPR OF THE DATA SET SPECIFIED BY SYSLIB COULD NOT BE FOUND.                                    
IEW2322I 1220  2    ORDER DDSYSTBL,DDCLLPR                                  
IEW2322I 1220  3    ENTRY DDSYSTBL                                          
IEW2322I 1220  4    MODE AMODE(31),RMODE(24)                                
IEW2322I 1220  5    NAME DDSRTLM(R)                                          
IEW2454W 9203 SYMBOL DDCLLPR UNRESOLVED.  NO AUTOCALL (NCAL) SPECIFIED.      
IEW2470E 9511 ORDERED SECTION DDCLLPR NOT FOUND IN MODULE.                  

Cause

The DATACOM.R151.CAAXLOAD dataset was created at as a PDS and not a PDSE (Data set name type  : LIBRARY)

Resolution

Start the UPGRADE process all over again from the beginning and this time be sure that the DATACOM.R151.CAAXLOAD has been defined as a PDSE.
This resolved the errors that the customer was receiving.