Fleet management Locker Components are missing in VCF Operations
search cancel

Fleet management Locker Components are missing in VCF Operations

book

Article ID: 426403

calendar_today

Updated On:

Products

VCF Operations

Issue/Introduction

Product components for the connected Fleet Management 9.0.1 instance are visible within VCF Operations 9.0.1 under Fleet Management -> Lifecycle -> Product Components. However, certificates and passwords associated with these Fleet Management product components are not displayed in the VCF Operations 9.0.1 interface. 

In the /storage/vcops/log/vcops-bridge.log  file on the Operations node we see entry like:

SSLPeerUnVerifiedException: Host name 'fleetmanager_fqdn' does not match the certificate subject provided by the peer (CN=fleetmanager_hostname, OU=VCF, O=Broadcom, C=US)  

Environment

VCF Operations 9.x

Cause

SSL certificate issue between Fleet manager and VCF operations. it was observed that the Fleet manager certificate’s CN is set to a short hostname instead of a FQDN. 

Resolution

Regenerate the CA signed certificate for Fleet manager appliance making sure the certificate's CN has full FQDN of fleet manager appliance. Please follow the Replace a Certificate with an External CA-Signed Certificate document to replace the certificate.