Network Partition Due to Physical Network Connectivity Issue
search cancel

Network Partition Due to Physical Network Connectivity Issue

book

Article ID: 426274

calendar_today

Updated On:

Products

VMware vSAN VMware vSphere ESXi

Issue/Introduction

From vCenter your vSAN configuration exhibits one or more of the various condition below.

  • A single host reports vSAN Cluster Partition in Skyline Health.

  • Hosts with connectivity issues is reported in Skyline Health.

  • The affected host is isolated from the remaining vSAN cluster.

  • Virtual machines on the affected host may become inaccessible depending on the storage policy and object availability.

  • Bidirectional communication between the affected host and peer hosts over the vSAN VMkernel interface fails.

  • vSAN Cluster health status changes intermittently between Healthy (Green) and Critical (Red).

  • Skyline Health reports "vSAN cluster partition" and "Basic (unicast) connectivity check" failures.

  • Physical NICs (e.g., vmnic####) report link down events in host log.

  • vSAN 2 node stretch cluster in "split brain" scenario

Environment

  • VMware vSAN  8.x
  • Stretched Cluster configuration
  • Physical Inter-Switch Links (ISL)

Cause

  • The active physical uplink carrying the vSAN VMkernel traffic is unable to forward packets to the network even though ESXi reports the NIC as operational. Because the host cannot exchange vSAN traffic with its peers, it becomes isolated from the cluster, resulting in Skyline Health alarms such as:

    • Hosts with connectivity issues

    • vSAN cluster partition.

    • Intermittent connectivity loss on the physical Inter-Switch Links (ISL) or SFP modules between sites. This causes heartbeat loss between nodes, resulting in a network partition even if the local ESXi host shows the NIC link state as "Up.

    • This issue is typically external to ESXi and can be caused by:

    • Faulty switch port

    • Faulty network cable

    • Failed or partially failed physical NIC

    • Upstream network hardware issues

    • Incorrect switch forwarding despite the interface remaining operational

Since ESXi only monitors the NIC link state and hardware error counters, it may continue to report the adapter as healthy while the physical network path silently drops traffic.

  [root@###:~] vmkping -I vmk3 ##.##.##.## -d -s 1472
PING ##.##.##.## (##.##.##.##): 1472 data bytes
1480 bytes from ##.##.##.##: icmp_seq=0 ttl=64 time=0.142 ms
1480 bytes from ##.##.##.##: icmp_seq=1 ttl=64 time=0.140 ms
1480 bytes from ##.##.##.##4: icmp_seq=2 ttl=64 time=0.140 ms

Resolution

  • Move the vSAN traffic to another healthy physical uplink.

  • If connectivity is restored immediately, investigate the original physical network path.

The following components should be validated by the internal networking or hardware team:

  • Switch port

  • Network cable

  • SFP/transceiver (if applicable)

  • Physical NIC

  • Top-of-Rack switch

  • Port-channel/LACP configuration (if applicable)

Additional Information

    • Look for vob.net.vmnic.linkstate.down or LACP transition warnings in /var/run/log/vobd.log: [vob.net.vmnic.linkstate.down] vmnic vmnic0 linkstate down [1].

       /var/run/log/vobd..log :

    2026-01-12T02:30:51.298Z In(14) vobd[2097812]:  [netCorrelator] 354098842283us: [vob.net.vmnic.linkstate.down] vmnic vmnic0 linkstate down
    2026-01-12T02:30:51.527Z In(14) vobd[2097812]:  [netCorrelator] 354099070966us: [vob.net.lacp.uplink.transition.down] LACP warning: Uplink vmnic0 on VDS DvsPortset-0 moved out of the link aggregation group.
    2026-01-12T02:30:51.527Z In(14) vobd[2097812]:  [netCorrelator] 354099024161us: [esx.problem.net.lacp.uplink.transition.down] uplink vmnic0 on VDS DvsPortset-0 is moved out of link aggregation group.
    2026-01-12T02:30:51.527Z In(14) vobd[2097812]:  The event ([esx.problem.net.lacp.uplink.transition.down] uplink vmnic0 on VDS DvsPortset-0 is moved out of link aggregation group.) was sent immediately to hostd;
    2026-01-12T02:30:52.002Z In(14) vobd[2097812]:  [netCorrelator] 354099498857us: [esx.problem.net.vmnic.linkstate.down] Physical NIC vmnic0 linkstate is down
    2026-01-12T02:30:52.002Z In(14) vobd[2097812]:  The event ([esx.problem.net.vmnic.linkstate.down] Physical NIC vmnic0 linkstate is down) was sent immediately to hostd;
    2026-01-12T02:35:37.701Z In(14) vobd[2097812]:  [netCorrelator] 354385245465us: [vob.net.vmnic.linkstate.down] vmnic vmnic1 linkstate down 

  • Packet loss may appear while performing the ping connectivity test between hosts .