ESXi experiences a psod and produces the following backtrace:
Panic Message: @BlueScreen: #PF Exception 14 in world ********:vmm: IP 0x************ addr 0x************
Backtrace:
TimerNextExpiry@vmkernel#nover+0x53 stack:
Timer_BHHandler@vmkernel#nover+0xa4 stack:
BH_DrainAndDisableInterrupts@vmkernel#nover+0x96 stack:
IntrCookie_VmkernelInterrupt@vmkernel#nover+0xa9 stack:
IDT_IntrHandler@vmkernel#nover+0x97 stack:
gate_entry@vmkernel#nover+0x68 stack:
Power_ArchPerformWait@vmkernel#nover+0xd4 stack:
Power_ArchSetCState@vmkernel#nover+0xba stack:
CpuSchedIdleLoopInt@vmkernel#nover+0x285 stack:
CpuSchedDispatch@vmkernel#nover+0x1f12 stack:
CpuSchedWait@vmkernel#nover+0x353 stack:
CpuSchedVcpuHaltWork@vmkernel#nover+0x157 stack:
VMMVMKCall_Call@vmkernel#nover+0x10b stack:
VMKVMM_ArchEnterVMKernel@vmkernel#nover+0xe stack:
VMware vSphere ESXi 8x
A misbehaving cpu module attempts to retrieve an incorrect memory address then the correct one causing a page fault.
Contact hardware vendor to preform stress test of cpu modules.
Ensure bios & hardware on the server are up to date.
cpu replacement by vendor.