Experiencing latency and slow response time from virtual machines. Output from the following command
#localcli storage core adapter stats get
t10.NVMe__M.2_NVMe_22DBay_RAID_Kit______XXXXXXXXXXXXXXXX:
Device: t10.NVMe__M.2_NVMe_22DBay_RAID_Kit______XXXXXXXXXXXXXXXX
vmhbax:
Successful Commands: 1721197 Blocks Read: 26583150 Blocks Written: 12088250 Read Operations: 614127 Write Operations: 1107036 Reserve Operations: 0 Reservation Conflicts: 0 Failed Commands: 42191752 Failed Blocks Read: 0 Failed Blocks Written: 0 Failed Read Operations: 38310731 Failed Write Operations: 3881020
ESXi 8.0 U3
vCenter 8.0 U3
The adapter has failed
#esxcfg-mpath -b
vmhba2:C0:T0:L0 LUN:0 state:dead pcie Adapter: Unavailable Target: Unavailable
Contact hardware vendor
Additional Information:
Link to Marvell Technology Group Ltd Lenovo ThinkSystem M.2 NVMe 2-Bay RAID Enablement Kit on the VMware by Broadcom Compatibility Guide.