Error: Unable to get request status during VCF Automation deployment
search cancel

Error: Unable to get request status during VCF Automation deployment

book

Article ID: 425177

calendar_today

Updated On:

Products

VMware SDDC Manager / VCF Installer VCF Automation

Issue/Introduction

The VCF Installer workflow fails during VCF Automation (VCF-A) deployment. This article outlines the procedure to bypass a failed VCF-A deployment task, allowing the component to be deployed later as a Day-N operation.

Symptoms:

  • The VCF Installer workflow may fail during the VCF Automation (VCF-A) deployment stage with following errors:

    • VCF services runtime FQDN is not on the management network.

    • Not all addresses from the VCF Management Services IPv4 pool are part of the management network range.

    • Not all ESXi Hosts in the cluster are connected to the datastore

  • After a failed deployment, if the VCF Automation (VCF-A) VM is manually removed from inventory and the deployment is retried:

    • VCF Installer UI shows following error message:

      Retrieve the status of VCF Automation Deployment request - Failed - MM/DD/YY, HH:MM
      Unable to get request status for request <Request_ID> Reference Token: ######
    • /var/log/vmware/vcf/domainmanager/domainmanager.log in VCF installer displays the following message:

      YYYY-MM-DDTHH:MM:SS.###+0000 DEBUG [vcf_dm,<Task_ID>,####] [c.v.e.s.r.c.LoggingHttpRequestInterceptor,dm-exec-##]  Request URI: https://<VCF_FLEET_MANAGER_FQDN>/lcm/request/api/v2/requests/<Request_ID>
      >Request method: GET
      >Request body:
      >Response code: 404 NOT_FOUND

Environment

  • VMware Cloud Foundation 9.x
  • VCF Automation 9.x
  • VCF Installer 9.X

Cause

The VCF Installer workflow requires an active and reachable VCF Automation (VCF-A) virtual machine to proceed. As the VM was deleted, the installer receives a 404 NOT_FOUND response when attempting to query or communicate with the appliance, causing the workflow to fail.

Resolution

If the VCF Automation (VCF-A) VM has been deleted or it is decided to deploy VCF Automation as a Day-N activity, the failed VCF-A task(s) must be skipped directly in the VCF Installer database to allow the primary workflow to complete.
  1. To request assistance with skipping this task, Contact Broadcom Support.
  2. Once the task is skipped and the main installer completes, VCF-A can be deployed as a Day-N activity by following the VCF Management Components - Deploy Use Case