Edge node is showing MPA connectivity down in NSX UI and tunnels from the edge are not establishing.
VMware NSX
The network adapters (vNICs) used for Edge management must remain connected for the Edge node to maintain network connectivity. If the management vNIC is disconnected, the Edge node will lose network connectivity.
Log in to the vSphere Client.
Navigate to Menu → Hosts and Clusters.
Locate and select the affected NSX Edge Node VM.
Right-click the Edge VM and select Edit Settings.
Expand the Network adapter associated with the Edge Management network.
Verify the following:
Connected is checked
Connect At Power On is enabled
If the adapter is disconnected, select Connected and click OK to apply the changes.
Wait a few minutes and verify:
MPA connectivity shows UP in the NSX UI
Edge tunnels start establishing successfully
The Edge node is reachable via ping from other VMs/Edges on the same network