After LU09907 MUF startup fails with S008, S47B and S0C1 in DBSRPPR
search cancel

After LU09907 MUF startup fails with S008, S47B and S0C1 in DBSRPPR

book

Article ID: 424748

calendar_today

Updated On:

Products

Datacom/AD Datacom Datacom/DB

Issue/Introduction

After applying Datacom PTFs LU09907 and LU16719 the MUF fails with S008 early in startup and no other messages

CCSR010E DBMUFPR S008 at 00000000 LMOD N/A CSECT N/A +N/A DATACOM N/A DATACOM
CCSR061I PSW: 00000000 00000000 00000000 00000000
CCSR062I ILC: 00 INTERRUPT CODE: 00
CCSR067I COMPLETION CODE S008 REASON CODE 00000000

    331             SYSTEM COMPLETION CODE=0C1  REASON CODE=00000001
    331              TIME=08.53.40  SEQ=00096  CPU=0000  ASID=0040
    331              PSW AT TIME OF ERROR  078D0400   80000002  ILC 2  INTC 01
    331                NO ACTIVE MODULE FOUND

 CCSR010E DBMUFPR S47B at 10B03688 LMOD DBMUFPR CSECT DBMUFPR +003688 N/A N/A N/A

Cause

PTF LU09907 has a missing PRE for LU09872.

A PRE for LU09872 was added to later PTF LU10808 to resolve this, but LU16719  which SUPs  LU10808 doesn't PRE LU09872.

Resolution

Apply PTF LU09872