Creating a new workload domain with a shared NSX Manager fails during the validation phase with an image compatibility error in SDDC Manager.
Although the NSX Manager appears as shareable in the UI, the workload domain creation is blocked during validation. The error indicates a mismatch between the ESXi version in the source workload domain and the compatible ESXi version defined in the Lifecycle Manager (LCM) Bill of Materials (BoM).
An error similar to the following is displayed:
ESXi version 9.0.1.0.24897405 is different from the compatible LCM ESXi BOM versions [9.0.0.0.24755229]
VMware Cloud Foundation 9.0
This issue occurs when the NSX Manager is reused from a workload domain running a split BoM, where:
To resolve this issue, ensure ESXi version compatibility between the domain providing the shared NSX Manager and the LCM BoM.
Use one of the following workarounds:
Upgrade the ESXi hosts in the workload domain that provides the shared NSX Manager to the corresponding LCM supported ESXi version, or Use a different NSX Manager from a workload domain where the ESXi hosts are already running a compatible ESXi version.
After ensuring version alignment, retry the workload domain creation