During Workload Domain deployment or expansion within VMware Cloud Foundation (VCF), the orchestration process fails during the datastore availability validation task.
The following error strings are observed in the VCF-OPS UI:
Message: Failed to create file inside datastore datastore-## of datacenter
datacenter-#
Remediation Message: Check whether datastore datastore-##of datacenter
datacenter-## is accessible
Log Snippet :
error vpxd[19801] [Originator@6876 sub=Default opID=2f8a494] [VpxLRO] -- ERROR lro-107140 -- 52203526-2461-57b1-92d6-21ab3bc2fa30(52e9f88e-9f9c-539d-5d67-07adaf4a527b) -- FileManager -- vim.FileManager.makeDirectory: vim.fault.CannotCreateFile
Result:
--> (vim.fault.CannotCreateFile)
faultCause = (vmodl.MethodFault) null,
faultMessage = (vmodl.LocalizableMessage) [
(vmodl.LocalizableMessage) {
key = "vob.vsan.vsanprovider.object.creation.failed",
arg = unset,
message = "Failed to create object."
},
(vmodl.LocalizableMessage) {
key = "vob.vsan.clomd.needMoreFaultDomains2",
arg = (vmodl.KeyAnyValue) [
(vmodl.KeyAnyValue) {
key = "1",
value = "1"
},
(vmodl.KeyAnyValue) {
key = "2",
value = "2"
}
],
message = "There are currently 1 usable fault domains. The operation requires 2 more usable fault domains."
}
],
file = "[vSAN-Datstore] vcf-test-"
msg = "Received SOAP response fault from [kcs: p:00007faf8c5b9d50, PIPE:/var/run/envoy-hgw/hgw-pipe>, /hgw/host-28/vpxa>]: MakeDirectory
Received SOAP response fault from [<SSL(<io_obj t:N7Vmcore6System19TCPSocketObjectAsioE, h:18, <TCP '127.0.0.1 : 49978'>, <TCP '127.0.0.1 : 443'>>), /sdk>]: makeDirectory
Cannot complete file creation operation."
-->
Args:
--> Arg name:
"[Datastore-name] vcf-domain"
--> Datacenter:
'vim.Datacenter:datacenter-#'
--> createParentDirectories:
true
info vpxd[19797] [Originator@6876 sub=vpxLro opID=11fcf212] [VpxLRO] -- BEGIN lro-107141 -- SessionManager -- vim.SessionManager.logout -- 52203526-2461-57b1-92d6-21ab3bc2fa30(52e9f88e-9f9c-539d-5d67-07adaf4a527b)
VMware Cloud Foundation 9.x
The Workload Domain creation failed due to insufficient fault domains on vSAN Datastore
To restore vSAN cluster communication and satisfy the storage policy requirements
Please follow the steps mentioned : "There are currently [X] usable fault domains. The operation requires [Y] more usable fault domains" in vSAN.
If you encounter any difficulties, please raise a case with the Broadcom support team.
Verify the vSAN transport layer end-to-end MTU matching parameters. Ensure a uniform Jumbo Frame specification of 9000 is configured uniformly across all host VMkernel ports (vmknic), Distributed Virtual Switches, and physical switch interface ports assigned to vSAN traffic to prevent silent network drops during large object sync transactions.