The VCF Management page under Operations Manager > Build > Lifecycle may fail to render, appearing completely blank. Navigating to the frame source URL results in an HTTP ERROR 500. This issue occurs due to a transient service failure or state inconsistency within the Fleet LCM UI service or VCF runtime nodes responsible for serving the management interface. This article provides steps to resolve the inconsistency by restarting the affected services.
{"message":"Identity Internal Server Error","code":"IDENTITY_INTERNAL_SERVER_ERROR","status":500}
VCF Operations 9.1.x
The issue is caused by a data node in the VCF Operations cluster remaining in a "Waiting for Analytics" state. While the analytics service may appear as "running" via an SSH console, the cluster is only partially online. This inconsistent state prevents the API from returning a successful 200 response to the Lifecycle Manager interface, resulting in a timeout or 500 error.
Perform a clean restart of the VCF Operations cluster and associated nodes to clear the service inconsistency:
https://<vcf_ops_fqdn>/admin).Primary Node, then Replica, followed by Data and Witness Nodes).Waiting for Analytics" state.