ESX PSODed due to panic related to nsxt-vdl2
search cancel

ESX PSODed due to panic related to nsxt-vdl2

book

Article ID: 422755

calendar_today

Updated On:

Products

VMware vSphere ESXi VMware NSX

Issue/Introduction

  • Large scale environment managed by a single NSX Manager cluster.
  • NSX is configured on ESXi.
  • ESXi goes down with a PSOD after support bundle collection. 
  • PSOD screen includes the line-
           
           "Module(s) involved in panic: [nsxt-vdl2-####]"

Environment

  • VMware NSX-T 3.2.x
  • VMware NSX 4.x
  • VCF 9.0.1

Cause

In large-scale deployments where the number of unique virtual TEP (VTEP) entries across all logical switches and routing domains on a host exceeds 2048, collecting a support bundle triggers a buffer overrun in the nsxt-vdl2 module.

Resolution

This is a known issue impacting VMware NSX and fixed in versions 4.2.3.3, 4.2.4 and 9.1

Workaround:

  1. Don't collect support bundle on esx host if number of global vtep entries are more than 2048.
  2. Second workaround would be to reduce the scale of LS/RD vtep spans so that global vtep count is less than 2048.
  3. There is a workaround script developed by Broadcom to prevent PSOD after the support bundle collection.  For more information, please open a support case with Broadcom. Creating and managing Broadcom support cases