The work processes (WPs) constantly create forced traces with these messages:
U00029108 UCUDB: SQL_ERROR Database handles DB-HENV: 3f0cf740 DB-HDBC: 3f12c980
U00003591 UCUDB - DB error info: OPC: 'OCIStmtFetchx' Return code: 'ERROR'
U00003592 UCUDB - Status: '' Native error: '1455' Msg: 'ORA-01455: converting column overflows integer datatype'
U00003590 UCUDB - DB error: 'OCIStmtFetchx', 'ERROR ', '', 'ORA-01455: converting column overflows integer datatype'
U00003620 Routine 'UCDS_R' forces trace because of error.
U00003590 UCUDB - DB error: 'OCIStmtFetchx', 'ERROR ', '', 'ORA-01455: converting column overflows integer datatype'
U00003449 Output to the TRACE file is finished.
U00003100 Memory TRACE was opened with the switches '0000000000000000'.
Automic Automation Engine 24.4.X
OS: AIX 7.3
Database: Oracle 19c
A database column has exhausted its data type capacity.
DefectID: DE177418
Update to a fixed version listed below or a newer version if available.
Public Title:
WP generates forced traces with database error
Public Description:
A problem has been fixed which caused forced traces with a database error stating ORA-01455: converting column overflows integer datatype
Article title: How to register to Broadcom Software Product updates and Critical Alerts
https://knowledge.broadcom.com/external/article?articleId=133819
Component: Automation.Engine
Automation Engine 24.4.3 - Available