Elevated disk group latency observed on a single host within the vSAN cluster.
Extreme %WAIT and %VMWAIT values in esxtop (e.g., system world values exceeding 50,000).
Guest OS scheduling stalls on database-intensive workloads.
On the ESXi host, the Monitor > vSAN > Performance view shows a sudden spike in the Delayed I/O Average Latency counter.
VMware vSAN 8.x
This issue is typically driven by two concurrent factors:
Review the following logs and metrics to confirm the root cause:
YYYY-MM-DDTHH:MM:SS.MS+HH:MM [291729295] [cpu12] [4b69a9ba OWNER [MASKED OWNER] VMDISK] DOMTraceOperationNeedsRetry:4483: {'op': 0x45bc1c9d47c0, 'objUuid': '########-####-####-####-############', 'pendingUpdatesListLen': 128, 'inclusiveCommitCount': 0, 'prepWaitQueueLen': 0, 'status': 'VMK_LIMIT_EXCEEDED'}YYYY-MM-DDTHH:MM:SS.MS+HH:MM [291729296] [cpu12] [4b69a9bc OWNER [MASKED OWNER] VMDISK] DOMTraceOperationNeedsRetry:4483: {'op': 0x45bc1cf8f580, 'objUuid': '########-####-####-####-############', 'pendingUpdatesListLen': 128, 'inclusiveCommitCount': 0, 'prepWaitQueueLen': 1, 'status': 'VMK_LIMIT_EXCEEDED'}YYYY-MM-DDTHH:MM:SS.MS+HH:MM In(182) vmkernel: cpu35:2098582)CMMDS: CMMDSCompleteLocalUpdate:3865: ########-####-####-####-############: Number of slow updates in last interval is 1 maxLatency 302 millisecs slowest UUID67ecd62f-####-####-####-############YYYY-MM-DDTHH:MM:SS.MS+HH:MM In(182) vmkernel: cpu63:2098582)CMMDS: CMMDSCompleteLocalUpdate:3865: ########-####-####-####-############: Number of slow updates in last interval is 1 maxLatency 466 millisecs slowest UUID52301903-####-####-####-############To remediate congestion and increase cumulative queue depth, follow these architectural adjustments:
Workload Redistribution: Redistribute high-intensity workloads across multiple smaller VMDKs rather than a single large disk.
Controller Optimization: Attach new VMDKs to secondary VMware Paravirtual SCSI (PVSCSI) controllers to maximize I/O parallelism.
Infrastructure Updates: Verify that host BIOS, NIC drivers, and firmware are up to date, particularly on Nutanix or Dell hardware platforms.
Distributing the application workload across multiple smaller Virtual Disks (VMDKs) significantly improves throughput. Because each VMDK maintains an independent I/O queue, striping the data across multiple storage objects multiplies the total available queue depth.
This architectural adjustment prevents single-object bottlenecking, thereby reducing vSAN backend processing pressure and minimizing guest-level latency.
Refer kb https://knowledge.broadcom.com/external/article/416407 for more information on the Log Buffer Saturation.