While importing VMware Aria Automation version 8.18.x from Aria Suite Life Cycle Manager into Fleet Lifecycle Manager as a part of VCF Automation 9.0 upgrade (VCFA Import), the network properties for aria automation nodes may not populate correctly.
Specifically, the network information is missing for the primary and tertiary Aria Automation nodes in the Fleet Lifecycle Manager UI, while the secondary node network information is available.
VCF Automation 9.0.x
The network information fails to populate for two of the Aria Automation nodes (primary) during the import process due to an issue where the node types were not correctly identified or synchronized in the VCF Ops Fleet Lifecycle Manager database.
Broadcom Engineering team is aware of the issue and this will be fixed in future versions.
The workaround involves swapping the node types of the affected primary and a working secondary node within the VCF Fleet Lifecycle Manager database to enable the upgrade to proceed.
The resolution requires a direct database update on the VCF Fleet manager appliance and should be performed with caution. Before proceeding, it is critical to take a snapshot of the VCF Fleet Manager appliance.
cd /opt/vmware/vpostgres/current/binsu postgres./psql -d vrlcm
select * from vm_lcops_product where id='vra';
product_vmid obtained in the previous step. Replace <VMID-of-AA (Aria Automation)-product> with the actual ID:select * from vm_lcops_product_nodes where product_vmid='<VMID-of-AA-product>';
update vm_lcops_product_nodes set type='vrava-secondary' where vmid='[vmid of current primary node]';update vm_lcops_product_nodes set type='vrava-primary' where vmid='[vmid of current secondary node with network info]';NOTE : Do not perform an inventory sync before triggering the upgrade.