vCenter Becomes Inaccessible After vMotion Due to Incorrect VLAN Configuration
book
Article ID: 421993
calendar_today
Updated On:
Products
VMware vCenter Server
Issue/Introduction
- After performing a vMotion of the vCenter virtual machine, vCenter Server is unable to connect over the configured VM network.
- The vMotion task completes successfully, but network connectivity to the vCenter Server is lost.
Cause
- The destination ESXi host is not configured with the required VLAN ID for the VM network.
- The VM network on the destination host is misconfigured with the wrong VLAN ID, resulting in loss of network connectivity after migration.
Resolution
- Review and confirm that both the source and destination ESXi hosts have consistent and matching VLAN settings for the VM network.
- Edit the VM network settings on the destination ESXi host to match the working settings on the source ESXi host the vCenter was migrated from.
- Configure the correct VLAN ID for the port group used by the vCenter virtual machine.
- After updating the VLAN configuration, verify that the vCenter Server is accessible by the management network.
Feedback
thumb_up
Yes
thumb_down
No